Iliac anastomotic stenting with a biodegradable poly-L-lactide stent: a preliminary study after 1 and 6 weeks

CM Bünger, N Grabow, K Sternberg… - Journal of …, 2006 - journals.sagepub.com
After transverse graft incision, 17 316L stainless steel stents and 17 PLLA stents were
randomly implanted at both iliac anastomotic sites and deployed with a 6-mm balloon under direct …

[引用][C] Erratum: Iliac anastomotic stenting with a biodegradable poly-L-lactide stent: A preliminary study after 1 and 6 weeks (Journal of Endovascular Therapy (August …

CM Bünger - Journal of Endovascular Therapy, 2006 - vivantes.elsevierpure.com
Research units Research output … Report vulnerability …

A biodegradable stent based on poly (L-lactide) and poly (4-hydroxybutyrate) for peripheral vascular application: preliminary experience in the pig

CM Bünger, N Grabow, K Sternberg… - Journal of …, 2007 - journals.sagepub.com
Iliac anastomotic stenting with a biodegradable polyL-lactide stent: a preliminary study after
1 and 6 weeks. … sirolimus-eluting biodegradable poly-L-lactide stent: a preliminary study after

Sirolimus-eluting biodegradable poly-L-lactide stent for peripheral vascular application: a preliminary study in porcine carotid arteries

CM Bünger, N Grabow, K Sternberg, C Kröger… - … of Surgical Research, 2007 - Elsevier
… PLLA stents after 1 and 6 weeks. S: stent strut; because of histological preparation, stent struts
… We have recently reported our experiments with iliac anastomotic stenting using PLLA in …

Iliac anastomotic stenting with a sirolimus-eluting biodegradable poly-L-lactide stent: a preliminary study after 6 weeks

CM Bünger, N Grabow, C Kröger… - Journal of …, 2006 - journals.sagepub.com
… sirolimus-loaded PLLAs, and 6 unloaded stainless steel (316L) stents were randomly
implanted at both iliac anastomotic sites. Stents were deployed with a 6-mm balloon under direct …

Anastomotic stenting in a porcine aortoiliac graft model

CM Bünger, N Grabow, K Hauenstein… - Laboratory …, 2007 - journals.sagepub.com
… of the study was to evaluate the feasibility of anastomotic stent … In a total of 10 pigs, a
polytetrafluoroethylene aortobi-iliac … ), six biodegradable PLLA stents and four biodegradable

Comparison of early vascular morphological changes between bioresorbable poly-L-lactic acid scaffolds and metallic stents in porcine iliac arteries

Y Sekimoto, H Obara, K Matsubara, N Fujimura… - …, 2017 - Taylor & Francis
Iliac anastomotic stenting with a sirolimus-eluting biodegradable poly-L-lactide stent: a
preliminary study after 6 weeks. J Endovasc Ther 2006; 13:630-9; PMID:17042669; http://dx.doi.…

[PDF][PDF] Poly-L/D-lactide stents as intravascular devices-an experimental study

EM Hietala - 2004 - helda.helsinki.fi
… implantation and during the early phase of biodegradation. … This stent was made of
poly-L-lactide, with at least … The exact location of the PLA stents, in regard to renal and iliac

Mechanical properties of a biodegradable balloon-expandable stent from poly (L-lactide) for peripheral vascular applications

N Grabow, CM Bünger, K Sternberg, S Mews… - 2007 - asmedigitalcollection.asme.org
… For the manufacture of the stents a balloon-expandable stent design, which we have …
stent is investigated by our group as an anastomotic support stent in the porcine iliac artery. …

A Biodegradable Slotted Tube Stent Based on Poly(l-lactide) and Poly(4-hydroxybutyrate) for Rapid Balloon-Expansion

N Grabow, CM Bünger, C Schultze, K Schmohl… - Annals of biomedical …, 2007 - Springer
… polymeric stents due to the viscoelastic material behavior. This … iliaca with a follow-up of
6 weeks.4,8 … used by our group as an anastomotic support stent in the porcine iliac artery. …